IMG Publications

ListFilter
Export 237 results:
Sort by: Author [ Title  (Desc)] Type Year
Filters: Author is Huikai Xie  [Clear All Filters]
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
W
J. Li, K. D. T. Ngo, G-Q. Lu, and H. Xie, "Wafer-level fabrication of high-power-density MEMS passives based on silicon molding technique", Integrated Power Electronics Systems (CIPS), 2012 7th International Conference on, pp. 1-5, March, 2012.
J. Li, K. D. T. Ngo, G-Q. Lu, and H. Xie, "Wafer-level fabrication of high-power-density MEMS passives based on silicon molding technique", Integrated Power Electronics Systems (CIPS), 2012 7th International Conference on, pp. 1-5, March, 2012.
V
D. Torres, T. Wang, J. Zhang, X. Zhang, S. Dooley, X. Tan, H. Xie, and N. Sepulveda, "VO₂-Based MEMS Mirrors", Journal of Microelectromechanical Systems, pp. 780-787, 2016.
S J. Lee, J. Sun, M. King, H. Xie, and M. Sarntinoranont, "Viscoelastic Property Changes of Acute Rat Brain Tissue Slices As A Function Of Cell Viability", ASME 2011 Summer Bioengineering Conference (SBC2011), Famington, Pennsylvania, USA, June 22-25, 2011.
U
C. Y. Li, G. M. Li, V. O. K. Li, P. K. A. Wai, H. Xie, and X. C. Yuan, "Using 2 x 2 switching modules to build large 2-D MEMS optical switches", GLOBECOM '03. IEEE Global Telecommunications Conference (IEEE Cat. No.03CH37489)GLOBECOM '03. IEEE Global Telecommunications Conference (IEEE Cat. No.03CH37489), vol. 5, San Fransico, CA, USA, IEEE, pp. 2798 - 2802, 2003. Abstract  Download: Using 2x2 switching modules to build large 2-D MEMS optical switches.pdf (249.64 KB)
T
A. Jain, T. Xie, Y. Pan, G. K. Fedder, and H. Xie, "A Two-Axis SCS Electrothermal Micromirror for Biomedical Imaging", 2003 IEEE/LEOS International Conference on Optical MEMS, Waikoloa, Hawaii, August, 2003.
A. Jain, A. Kopa, Y. Pan, G. K. Fedder, and H. Xie, "A Two-Axis Electrothermal Micromirror for Endoscopic Optical Coherence Tomography", IEEE Journal of Selected Topics in Quantum Electronics, vol. 10, issue 3, pp. 636 - 642, 05/2004.
L. Wu, and H. Xie, "A tunable microlens with 0.9 mm scan range and small lateral shift", Optical MEMS and Nanophotonics, 2009 IEEE/LEOS International Conference on, pp. 69 -70, 2009.
A. Jain, and H. Xie, "A Tunable Microlens Scanner with Large-Vertical-Displacement Actuation", 18th IEEE International Conference on Micro Electro Mechanical Systems (MEMS 2005), pp. 92-95, Miami Beach, FL, IEEE, pp. 92-95, 01/2005.
X. Dai, L. Xi, C. Duan, H. Yang, H. Xie, and H. Jiang, "A tri-modal miniature probe for in vivo imaging", Optical Tomography and SpectroscopyBiomedical Optics 2016, Fort Lauderdale, FloridaWashington, D.C., OSA, pp. OTu4C.6, 2016.
W. Liao, W. Liu, J. E. Rogers, Y. Tang, B. Wang, and H. Xie, "A tip-tilt-piston piezoelectric scanning micromirror with folded PZT unimorph actuators", Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS EUROSENSORS XXVII), 2013 Transducers Eurosensors XXVII: The 17th International Conference on, pp. 526-529, June, 2013.
W. Liao, W. Liu, Y. Tang, B. Wang, and H. Xie, "Tip-tilt-piston piezoelectric micromirror with folded PZT unimorph actuators", Nano/Micro Engineered and Molecular Systems (NEMS), 2013 8th IEEE International Conference on, pp. 969-972, April, 2013.
L. Fu, A. Jain, C. Cranfield, H. Xie, and M. Gu, "Three-dimensional nonlinear optical endoscopy", Journal of Biomedical Optics, vol. 12, no. 040501, 07/2007.
L. Liu, and H. Xie, "Three-dimensional confocal scanning microscope using an MEMS mirror for lateral scan and an MEMS lens scanner for depth scan", Optical MEMS and Nanophotonics (OMN), 2012 International Conference on, pp. 158-159, Aug, 2012.
S
M. Wang, K. Ngo, and H. Xie, "SU8 Enhanced High Power Density MEMS Inductors", Proc. of the 34th Annual Conference of the IEEE Industrial Electronics Society (IECON’08), Orlando, FL, USA, Nov. 10-13, 2008.
S. Todd, and H. Xie, "Steady-state 1D electrothermal modeling of an electrothermal transducer", Journal of Micromechanics and Microengineering, vol. 15, issue 12, pp. 2264 - 2276, 12/2005. Abstract  Download: Steady-state 1D electrothermal modeling of an electrothermal transducer.pdf (606.38 KB)
H-C. Park, X. Zhang, J. Mavadia-Shukla, W. Yuan, X. Li, and H. Xie, "SPIE ProceedingsElectro-thermal MEMS fiber scanner for endoscopic optical coherence tomography (Conference Presentation)", SPIE BiOSOptical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XX, vol. 9697, San Francisco, California, United States, SPIE, pp. 96970O, 2016.
A. Sadat, Y. Liu, J. Yuan, and H. Xie, "Soft breakdown effects on MOS switch and passive mixer", 2004 IEEE International Reliability Physics Symposium.2004 IEEE International Reliability Physics Symposium. Proceedings, Phoenix, AZ, USA, IEEE, pp. 653 - 654, 04/2004. Abstract  Download: Soft breakdown effects on MOS switch and passive mixer.pdf (107.99 KB)
K. Jia, S. Samuelson, and H. Xie, "Single-wafer solution and optical phased array application of micro-mirror arrays with high fill factor and large sub-apertures", 2010 IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS)2010 IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS), Wanchai, Hong Kong, China, IEEE, pp. 180 - 183, 2010.
W. Wang, J. Chen, A. S. Zivkovic, C. Duan, and H. Xie, "A silicon based Fourier transform spectrometer base on an open-loop controlled electrothermal MEMS mirror", TRANSDUCERS 2015 - 2015 18th International Solid-State Sensors, Actuators and Microsystems Conference2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS), Anchorage, AK, USA, IEEE, pp. 212 - 215, 7/2015.
H. Xie, Y. Pan, and G. K. Fedder, "A SCS Micromirror for Optical Coherance Tomographic Imaging", Sensors & Actuators, vol. 103, pp. 237-241, JAN, 2003.
H. Xie, Y. Pan, and G. K. Fedder, "A SCS CMOS micromirror for optical coherence tomographic imaging", MEMS 2002 IEEE International Conference. , Las Vegas, NV, USA, IEEE, pp. 495 - 498, 2002. Abstract  Download: A SCS CMOS micromirror for optical coherence tomographic imaging.pdf (420.6 KB)
L. Wu, and H. Xie, "A scanning micromirror with stationary rotation axis and dual reflective surfaces for 360° forward-view endoscopic imaging", Solid-State Sensors, Actuators and Microsystems Conference, 2009. TRANSDUCERS 2009. International, Denver, CO, USA, IEEE, pp. 2222 -2225, 2009.
L. Wu, and H. Xie, "A scanning micromirror with stationary rotation axis and dual reflective surfaces for 360", 15th International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers 2009), Denver, CO., June, 2009.
R
X. Zhang, B. Li, X. Li, and H. Xie, "A robust, fast electrothermal micromirror with symmetric bimorph actuators made of copper/tungsten", TRANSDUCERS 2015 - 2015 18th International Solid-State Sensors, Actuators and Microsystems Conference2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS), Anchorage, AK, USA, IEEE, pp. 912 - 915, 6/2015.
V F-G. Tseng, and H. Xie, "Resonant Inductive Coupling-Based Piston Position Sensing Mechanism for Large Vertical Displacement Micromirrors", Journal of Microelectromechanical Systems, vol. 25, issue 1, no. 1, pp. 207 - 216, 2/2016.
S. Pal, and H. Xie, "Repeatability study of an electrothermally actuated micromirror", Reliability Physics Symposium, 2009 IEEE International, Montreal, QC, pp. 549 -556, 2009. Abstract
Q. Chen, H. Zhang, X. Zhang, D. Xu, and H. Xie, "Repeatability study of 2D MEMS mirrors based on S-shaped Al/SiO2 bimorphs", Nano/Micro Engineered and Molecular Systems (NEMS), 2013 8th IEEE International Conference on, pp. 817-820, April, 2013.
S. Pal, K. Jia, S. Maley, and H. Xie, "Reduced order thermal modeling of a one-dimensional electrothermally actuated micromirror device", MEMS/MOEMS Components and Their Applications V. Special Focus Topics: Transducers at the Micro-Nano Interface, vol. 6885, San Jose, CA, USA, SPIE, pp. 68850B - 68850B-11, 01/2008. Abstract
P